Data collection sheet for
RO plant treatment
chemical recommendation

NEW CLIENT / NEW APPLICATION

S.No. Description Details
 1 Client name with full postal address and pin code
  Phone
  Fax
  Email
2 Attention to whom
Name
Designation
3 Subject
4 Our Sales Person (s) involved
5 Discussion over Phone/Direct Site Visit Phone Direct Site Visit
6 Discussed with whom
Name
Designation
7 Offer to be sent to Fax / Courier : If fax : Fax Number Courier Fax         Fax No.
8 Copies to be sent to ( ie CC to )
Name
Designation
9  No. of Plant
10 Make of the Plant
11 Age of the Plant
12  Capacity of plant  m3/h .
13 Whether it is a single stage or double stage
14  Type and Source of feed water    
15  End of use of the RO treated water
16 Feed Water Characteristics including Colloidal Silica and Silt Density Index
pH
Hardness - Calcium
Hardness - Magnesium
TDS
Silica
Free chlorine
TSS
Iron
Colloidal Silica
Silt Density Index
17 Reject water characteristics
pH
Hardness - Calcium
Hardness - Magnesium
TDS
Silica
Free chlorine
TSS
Iron
18 No. of pressure tubes / membrane housing
19 No. of membrane in each pressure tube / membrane housing
20 Size of the membrane Length & Dia
21 Make and code of membrane
22 Type of micron cartridge used in the micron filter (PP Spiral Wound / PP Spun Type)
23 Length, Diameter, Micron rating and make of the micron cartridge
24 Whether partial quantity of reject water is blended in the RO feed water? If so, please mention the percentage (or) Quantity
25 Type of membrane ( whether cellulose or thin film composite)
26 Whether the membrane is designed to treat good quality water / brackish water/ sea water / effluent.
27 Membrane Salt rejection capacity
28 % of recovery of the RO plant ( as per design ) %
29 % of recovery of the RO plant at present %
30 Feed flow rate
31 Permeate flow rate
32 Reject flow rate
33 Schematic diagram of the RO Plant including upstream/ downstream equipments. (One file of maximum size                                                  1MB can be Uploaded)
34 Capacity of the high pressure pump  m3/h
35 Designed optimum pressure of the high pressure pump  kg/cm2
36 Actual pressure of the high pressure pump at present.  kg/cm2
37 Frequency of membrane cleaning carried out by customer  month(s)
38 Chemicals used for cleaning of the membrane at present
39 Whether softener is available in the upstream Yes     No 
40 Whether HCL dosing is being done in the RO feed water Yes      No 
41 Whether any other chemicals like antiscalant / antioxidants / pH boosters are being dosed in the RO feed water.
Yes   No
42 Whether membrane cleaning system is available with the client. (non-corrosive pump capacity 3.0 -5.0 kgs/cm2, micron filter, chemical dosing tank with necessary PVC pipes and SS valves etc.,)
Yes   No
43 Whether Ultra filtration is there in the upstream
44 Whether O.R.P Monitor is there in the R.O. Plant
45 What is the free chlorine residual level maintained at the inlet of pressure sand filter?
46 If more than one pressure tube / membrane housing is available, whether they are connected in series or in parallel Kindly mention the array
47 Whether any pretreatment chemicals are used for RO feed water like coagulants / flocculants sodium hypochlorite etc., If so, please give details.    
48 Whether water testing facilities are avaliable at site Yes      No
49 Recommended Product (s)
50 Dosage details
51 Special Instruction (If any)
52 Date of Visit by you
53
Offer sent Date to Client